考古拉 发表于 2013-2-6 10:33:01

回复 6# 火星人

浪涌抗扰度测试时,如果是直流电源正极接地,那么正极对负极,就相当于负极对地? 此时是不是要按照标准中线对地的 阻抗来设置?

在EMCpartner 设备的说明书中, 关于对直流电源施加浪涌 有这样两段话:

2. Connect the DC power supply with EUT - Power 1. When ever possible connect the positive pin of the
dc source with L and the negative pin with PE. Only when a grounding of the EUT is no allowed connect
the negative pin with the neutral N of the TRANSIENT TRA2000IN6.
它建议用直流源正极接L端,用负极接PE端(这样才能提供线对地的12Ω阻抗),只有当EUT没有接地时,才把直流源负极接N端。


SURGE superimposing on dc
For this kind of test the dc voltage should be, if possible connected to L and PE on EUT-Power 1. Only for
this coupling path the coupling impedance is 10 Ω and 9 μF.
This is an advice from EMCP based on experience of customers, that protection devices has been
destroyed when SURGE test has been carried out with coupling impedance 18 μF and 2 Ohm between L
and N. In the real installation environment they never had a damage of the equal protection devices. In the
IEC 61000-4-5 no specific chapter is dealing with different d.c. sources. The only hints for Surge tests on
d.c. supply can be found in the single phase test set up examples.
    这样的操作(正极接L端,用负极接PE端)是因为客户的经验:发生器有效阻抗选择2Ohm时,实际环境中能很好工作的保护元件会经常损坏,
所以选择12Ohm的阻抗,这样施加到DC电源线上的能量就小一点,EUT就不容易损坏。



这里就有点混淆了。。。对接地的直流源应选择线对地的阻抗,还是选择线对线的阻抗?是依据标准,还是依据客户经验?

astin 发表于 2013-2-27 13:59:14

我觉得楼主的耐压测试理解有误,耐压测试是看绝缘要求,也就是看+24V与GND、+24V与保护地、GND与保护地等之间的绝缘要求。

emcbbs 发表于 2013-2-27 16:05:47

直流浪涌,组合波发生器1.2/50us电压波输出端阻抗中差模2ohm,共模12ohm;电压波10/700us输出阻抗为40ohm

emcbbs 发表于 2013-2-27 16:08:11

EUT接参考地,直流电源中正极对应发生器L,负极对应发生器PE;EUT未接参考地,直流电源中正极对应发生器L,负极对应发生器N。共模电流形成回路。

火星人 发表于 2013-2-28 16:10:01

回复 11# 考古拉

       一般来说应该是以标准为准,如果客户提出更高的要求则以客户为准。

       具体到实际测试仪器的接线方法,以我的经验应该是对直流线的测试采用独立的耦合网络,这样12ohm的阻抗比较容易实现,不管是“正”接地还是“负”接地。如果使用信号发生器自带的内部耦合网络则需要了解耦合网络的线路,根据具体线路采用合适的接法。

   使用信号发生器内部自带的耦合网络接线时需要考虑PE线是否能够承受足够大的电流。“正”和“负”接在L和N上,将“正”和地在EUT端短接。这个时候按照正常的测试方法测试,等于“正”和“负”之间测试使用2ohm,“负”和PE之间测试阻抗12ohm,“正”和PE之间的信号被短路。