CS 3 m ? 小于3米就可不测吗?
AC power portPower ports, which according to the manufacturers specification are not intended to be connected to power supplyequipment with a cable longer than 3 m, shall not be subjected to these tests. DC power portPower ports, which according to the manufacturers specification are not intended to be connected to power supplyequipment with a cable longer than 3 m, shall not be subjected to these tests. Signal line portIt only applies when the overall cable length between the EUT and another item of active equipment may be greater than 3 m 300 386, DC和信号口小于3米可以不测。EN 55024,信号口小于3米可以不测。
AC没有3米这回事。 AC一般都做CS,不过确实没注意标准里有你说得那个情况没,我下去查查这个标准学习学习。 請問AC port 與 DC port 的敘述, 從那本法規節錄呢?
Singal port 在 EN55022 / EN61000-6-1 / EN 61000-6-2 等 EMS 法規都有寫到. 哦 对了 我引用的是 300386 V1.5。1 有这个300386 V1.5。1标准吗,能否共享下。 回复 6# 孔今
應該是這份吧~
对就是这个
在http://pda.etsi.org/pda/queryform.asp 注册就可以免费下。
什么时候开始执行呢?